BKH M4 UPS
Cabinet power range 40 kVA – 520 kVA.
BKH series UPS single cabinet power range 20kVA up to 600kVA can be customized depending on loads and can support 4 units in parallel.
Production capability has a max capacity of 2.4MVA. The world-class digital UPS, with the latest 9 leading technology, all data index have reached modular UPS standard YD/T2165-2010 class 1 standard.
A reliable and highly competitive power supply for all industry.
| BKH – M4A | T120K | T200K | T320K | T520K |
|---|---|---|---|---|
| Capacity | 40kVA – 120kVA | 40kVA – 200kVA | 40kVA – 320kVA | 40kVA – 520kVA |
| Power Module Capacity | 40kVA | 40kVA | 40kVA | 40kVA |
| Power Module Weight | 39Kg / Unit | 39Kg / Unit | 39Kg / Unit | 39Kg / Unit |
| Module Size W * D * H | pending | pending | pending | pending |
| Physical Parameter | ||||
|---|---|---|---|---|
| Cabinet Size mm W * D * H | 600 * 800 * 1250 | 600 * 1100 * 2000 | 600 * 1100 * 2000 | 1200 * 1100 * 2000 |
| Cabinet Weight | 130Kg | 295Kg | 305Kg | 578Kg |
| Modules Number (Max) | 3 | 5 | 8 | 13 |
| Mains Input (AC) | ||||
|---|---|---|---|---|
| Phase | 3 phase +N+PE | 3 phase +N+PE | 3 phase +N+PE | 3 phase +N+PE |
| Voltage Range | 291V up to 492V (line-line) full load 200V up to 291V linearly decrease | 291V up to 492V (line-line) full load 200V up to 291V linearly decrease | 291V up to 492V (line-line) full load 200V up to 291V linearly decrease | 291V up to 492V (line-line) full load 200V up to 291V linearly decrease |
| Frequency Range | 35Hz up to 70Hz | 35Hz up to 70Hz | 35Hz up to 70Hz | 35Hz up to 70Hz |
| THDi | Less than 3% (full linear load) | Less than 3%(full linear load) | Less than 3%(full linear load) | Less than 3%(full linear load) |
| Power Factor | 0.995 | 0.995 | 0.995 | 0.995 |
| Bypass Range | -10% up to 10% (Customized: -10% up to -30% and 10% up to 20%) | -10% up to 10% (Customized: -10% up to -30% and 10% up to 20%) | -10% up to 10% (Customized: -10% up to -30% and 10% up to 20%) | -10% up to 10% (Customized: -10% up to -30% and 10% up to 20%) |
| Battery | ||||
|---|---|---|---|---|
| Connection Type | Positive series and negative series battery | Positive series and negative series battery | Positive series and negative series battery | Positive series and negative series battery |
| Rated Voltage | +/- 240VDC (Positive and negative series, each 20pcs * 12V) Can be customized | +/- 240VDC (Positive and negative series, each 20pcs * 12V) Can be customized | +/- 240VDC (Positive and negative series, each 20pcs * 12V) Can be customized | +/- 240VDC (Positive and negative series, each 20pcs * 12V) Can be customized |
| Battery Number | 40pcs / set (Can be customized from 30pcs up to 50pcs / set) | 40pcs / set (Can be customized from 30pcs up to 50pcs / set) | 40pcs / set (Can be customized from 30pcs up to 50pcs / set) | 40pcs / set (Can be customized from 30pcs up to 50pcs / set) |
| Charging Current | 20% * System power (battery capacity) | 20% * System power (battery capacity) | 20% * System power (battery capacity) | 20% * System power (battery capacity) |
| Output (Inverter) | ||||
|---|---|---|---|---|
| Output Voltage | 380VAC 3 phase 4 wires + PE | 380VAC 3 phase 4 wires + PE | 380VAC 3 phase 4 wires + PE | 380VAC 3 phase 4 wires + PE |
| Voltage Regulation | Less than +/- 1% | Less than +/- 1% | Less than +/- 1% | Less than +/- 1% |
| Phase Lock Range | 50Hz / 60Hz +/-5Hz; (Self frequency 50Hz / 60Hz +/-0.01Hz) | 50Hz / 60Hz +/-5Hz; (Self frequency 50Hz / 60Hz +/-0.01Hz) | 50Hz / 60Hz +/-5Hz; (Self frequency 50Hz / 60Hz +/-0.01Hz) | 50Hz / 60Hz +/-5Hz; (Self frequency 50Hz / 60Hz +/-0.01Hz) |
| Output Frequency | 50Hz / 60Hz +/-0.01Hz (turn into mains frequency if phase locked) | 50Hz / 60Hz +/-0.01Hz (turn into mains frequency if phase locked) | 50Hz / 60Hz +/-0.01Hz (turn into mains frequency if phase locked) | 50Hz / 60Hz +/-0.01Hz (turn into mains frequency if phase locked) |
| Power Factor | 1 | 1 | 1 | 1 |
| Crest Factor | 3:1 | 3:1 | 3:1 | 3:1 |
| THDu | THD less than 2% (linear load) THD less than 3% (non-linear load) | THD less than 2% (linear load) THD less than 3% (non-linear load) | THD less than 2% (linear load) THD less than 3% (non-linear load) | THD less than 2% (linear load) THD less than 3% (non-linear load) |
| Three Phase Voltage Unbalance Degree | Balance load: 0.5% 100% unbalance load : 1% | Balance load: 0.5% 100% unbalance load : 1% | Balance load: 0.5% 100% unbalance load : 1% | Balance load: 0.5% 100% unbalance load : 1% |
| Dynamic Voltage Transient Range | Less than 3% | Less than 3% | Less than 3% | Less than 3% |
| Transient Recovery Time | 0ms | 0ms | 0ms | 0ms |
| Three Phase Voltage Deviation | Mains: 0.4 Battery: 0.3 | Mains: 0.4 Battery: 0.3 | Mains: 0.4 Battery: 0.3 | Mains: 0.4 Battery: 0.3 |
| Transfer Time | Mains to battery: 0ms Inverter to bypass: 0ms | Mains to battery: 0ms Inverter to bypass: 0ms | Mains to battery: 0ms Inverter to bypass: 0ms | Mains to battery: 0ms Inverter to bypass: 0ms |
| Overload Capacity | 125% for 10min 150% for 1min Greater than 150% for 200ms (linear load) | 125% for 10min 150% for 1min Greater than 150% for 200ms (linear load) | 125% for 10min 150% for 1min Greater than 150% for 200ms (linear load) | 125% for 10min 150% for 1min Greater than 150% for 200ms (linear load) |
| System Efficiency | Greater than 96% | Greater than 96% | Greater than 96% | Greater than 96% |
| Environment Indicator | ||||
|---|---|---|---|---|
| Noise | Less than 68dB @100% load, cooling fan adopt intelligent speed control | Less than 68dB @100% load, cooling fan adopt intelligent speed control | Less than 68dB @100% load, cooling fan adopt intelligent speed control | Less than 68dB @100% load, cooling fan adopt intelligent speed control |
| Display | Touch screen LCD+LED | Touch screen LCD+LED | Touch screen LCD+LED | Touch screen LCD+LED |
| Interface | Standard: RS232, RS485, Dry contacts, SNMP card optional | Standard: RS232, RS485, Dry contacts, SNMP card optional | Standard: RS232, RS485, Dry contacts, SNMP card optional | Standard: RS232, RS485, Dry contacts, SNMP card optional |
| Operation Temperature | Temperature: -10ºC up to 40ºC Humidity 0% up to 98% Storage temperature -25ºC up to 75ºC Altitude (m): less than 1000m, 1000m-2000m above every 100m reduce 1% | Temperature: -10ºC up to 40ºC Humidity 0% up to 98% Storage temperature -25ºC up to 75ºC Altitude (m): less than 1000m, 1000m-2000m above every 100m reduce 1% | Temperature: -10ºC up to 40ºC Humidity 0% up to 98% Storage temperature -25ºC up to 75ºC Altitude (m): less than 1000m, 1000m-2000m above every 100m reduce 1% | Temperature: -10ºC up to 40ºC Humidity 0% up to 98% Storage temperature -25ºC up to 75ºC Altitude (m): less than 1000m, 1000m-2000m above every 100m reduce 1% |
| IP Class | IP30 (Removable dust filter) | IP30 (Removable dust filter) | IP30 (Removable dust filter) | IP30 (Removable dust filter) |
NOTE: Subject to changes without further notice!